SDI Riva Cem Resin Modified GIC
- Brand: SDI
-
( 16 Reviews )Rated 5.00 out of 5 based on 16 customer ratings16
US$51.00US$80.00 (-36%)
In stock
SDI Rivacem Resin Modified GIC
Riva cem
is a glass ionomer cement for restoration of primary teeth, core build-up and restoration of class III, V and limited class I cavities. This dental material has good adhesive bond properties to the tooth structure, allowing it to form a tight seal between the internal walls of the tooth.
- Allows minimal cavity preparation
- Less stress on margins and marginal seal
- Protects against secondary caries
- Promotes internal remineralization and surface strengthening
- Easier mixing and fast setting makes it easy to use
- Good colour match to tooth structure
- More durable, longer lasting restorations
Indications : Restoration of primary teeth, core build-up and restoration of class III, V and limited class l cavities
Contraindications : 1. Pulp Capping 2. In rare cases, the product may cause sensitivity to some persons. If such reactions are experienced, discontinue the use of product and refer to a physician.
INDICATIONS :-
Indicated material | type of restoration |
PFM | Crowns & Bridges |
Resin | Crown, bridges, inlays, onlays & posts (fiber-reinforced) |
Metal | Crown, bridges, inlays & onlays, orthodontic appliances & posts |
Ceramics (high strength) | Crowns & Bridges |
All- ceramic | Inlays |
Features :-
- Light tack cure option for quick and easy removal of excess cement
- High bond strength
- No Bisphenol A or derivatives
- Greater stain resistance
- Sustained fluoride release
Key Specifications :-
COMPOSITION :-
PASTE A | %wt | PASTE B | %wt |
2-hydroxyethylmethacarylate | 10-15 | acrylic acid polymer | 40-50 |
dimethacrylate component | 10-20 | methacrylate component | 5-10 |
glass powder | 60-70 |
TECHNICAL DATA :-
Paste / Paste ratio (g/g) | 2.0/1.0 |
Mixing time (min, sec.) | 0’15” |
Working time (min, sec.)1,2 (from start of mixing | 1’45” |
Excess cement: – Tack light cure | 5 second per surface For tack light curing, use a high power conventional polymerization device (460-480 nm) |
Excess cement: – Self-curing gel-phase2 | 1’45” after seating the restoration |
Setting time (min, sec.)2 (after seating the restoration | 4’30” |
Radiopacity | 1.5 mm Al |
CONTRA-INDICATIONS :-
1. Pulp capping
2. Product may cause skin irritations to some people. In such cases, discontinue use and seek medical attention. Any persons having known resin allergies should immediately discontinue use.
STORAGE AND HANDLING :-
Avoid excess heat and direct sunlight.
• Do not remove riva cem syringes from foil packets until ready to use.
• Store between 10°C and 25°C (50° – 77°F).
• If stored at cooler temperature allow product to reach room temperature prior to use.
• Use at room temperature between 20°C and 25°C (68° – 77°F)
• Store with cap securely attached to the syringe. Do not allow the pastes to dry out.
PRECAUTIONS :-
• For professional use only.
• Do not take internally.
• Do not use after expiry date.
• Caution :-
Federal Law restricts this device to sale by or on the order of a dentist.
Packaging :-
- 1 x 8.5gms syringe (Universal Light Yellow Shade)
- Available in double barrel syringe which can easily be hand mixed
Direction to Use :-
1. PREPARATION :-
a) Prepare tooth using standard clinical guidelines. b) For optimum adhesion, condition the tooth with riva conditioner (SDI Ltd.) for 10 seconds. Rinse thoroughly with water and remove excess water. c) In cases where pulp protection is necessary, use a calcium hydroxide liner or a resin-modified glass-ionomer liner such as riva bond LC P/L
2. MIXING PROCEDURE :-
a)Before each use, dispense a small amount to ensure even dispensing or to remove any dried out paste. Discard this material. b) Extrude required amount of pastes onto a mixing pad. Important: Ensure the thumb is positioned firmly in the middle of the plunger to obtain the correct dispensing ratio of the two pastes. c) Using a spatula, mix the two pastes together thoroughly for 15 seconds. Be careful not to incorporate air bubbles. Note: Do not expose riva cem paste directly to operatory light to avoid early setting of the material.
3. CEMENTATION PROCEDURE :-
a) Ensure the internal surface of the restoration to be seated is cleaned, dried and prepared according to manufacturer’s instructions. b) Apply a thin layer of cement to the bonding surface. c) Seat the restoration within 30 seconds of completion of mixing before any light curing is carried out.
Note: 1. Avoid overfilling crowns. 2. Room temperatures above 23°C/73°F will reduce the working time. d) Light cure any excess material for 5 seconds per surface using a high power LED curing light (460-480nm emission). e) Gently remove excess material using a scaler or explorer. Note: Excess can also be removed during self-curing gel stage (when cement feels rubbery), after 1 min 45 seconds. f) Maintain isolation for at least 4 min 30 seconds after seating of restoration.
Average Rating
5.00
Only logged in customers who have purchased this product may leave a review.
by Maya (verified owner)
excellent quality product. Greater stain resistance